Technical support is available from 8:00 a.m. to 5 p.m. CST

All other times, call:
800.890.8989 or
512.836.2242
Technical Support

Updated:  October 18 , 2010

Products: 

  DL.3 & DL.2 Digital Lights

  SHOWBEAM & SHOWGUN Automated Luminaires 

  SHOWPIX Pixelation Luminaire

Subject:  Tilt Bearing Standoff Damage

These fixtures all have PEM standoffs on each side of the yoke supporting the tilt bearing.

capscrews

Rough handling or overtightening the screws when servicing can cause the standoffs to shear off the plate.

brokenPEM

THIS DAMAGE DOES NOT CREATE A SAFETY HAZARD

Repair may be needed if the tilt homing sensor is affected.


To prevent this situation, do not torque the cap screws to more than 15 in/lb.


If you have this damage on a unit, Kit #80430136 has parts and instructions for replacing the PEM Standoff bracket.


 

 

High End Systems
Copyright © High End Systems, a Barco Company. All Rights Reserved. Specifications are subject to change without notice.