Technical support is available from 8:00 a.m. to 5 p.m. CST
All other times, call: 800.890.8989 or 512.836.2242
Updated: October, 2009
Product: Studio Command 1200
Subject: Thermal Switch Replacement
In certain circumstances, the thermal switch on Studio Command 1200 fixtures may open prematurely resulting the lamp dousing. If this occurs, you can obtain a higher rated thermal switch by contacting Technical Support.
Once you have received the new switch, use the following steps to install it in your fixture.
1. Remove head cover:
2. Remove rear cover by removing the 4 screws.
3. Locate the thermal breaker and disconnect wiring.
4. Remove the 2 switch mounting screws.
5. Install the new switch and reconnect the switch wires.